IQ Fractional Resampler (Upsampling and Downsampling)

VERSION 1 Published

Created on: May 7, 2008 7:02 AM by NI RF-Group - Last Modified:  May 7, 2008 7:07 AM by NI RF-Group

This example resamples IQ signal at fractional rates between 0.5 and 2.

(0.5 to 1- downsampling; 1 to 2- upsampling)


The details of the IP are as follows:

1. Filter details:

Filter type: Multirate FIR low pass Filter

Passband= 0 to 0.4Fs (Fs= input sampling rate)

Transition band= 0.4 Fs to 0.6Fs

Passband ripple= 0.001 dB

Stopband attenuation= 85 dB

Interpolation factor= 128

2. Resampling rate= (Input sampling rate * Sampling rate conversion factor) <= clock rate/2

3. Maximum clock rate= 50MHz

4. Device utilization summary of the IP:

Number of BUFGMUXs 6 out of 16 37%
Number of External IOBs 371 out of 556 66%
Number of MULT18X18s 54 out of 136 39%
Number of RAMB16s 27 out of 136 19%
Number of SLICEs 4281 out of 13696 31%

Other requirments: Fixed point math library for LabVIEW FPGA



REQUIREMENTS:
Application Software: LabVIEW Professional Development System 8.5.1
Driver Software: NI-5640R 1.2
Hardware Family: RF,Reconfigurable I/O (RIO)
Addon Software: LabVIEW FPGA Module 8.5
Development Topic: Advanced Signal Processing,FPGAs,Fixed-Point
Downloads:
Average User Rating