NIYANTRA Documents

cancel
Showing results for 
Search instead for 
Did you mean: 

New NIYANTRA 2013 - Relay Testing and Monitoring using LabVIEW

(Make sure you follow all the 3 steps involved in submission. This is only Step 2 of 3. For details, visit http://bit.ly/16iNfUL)

Contact Information

Name of the College :Sri Shakthi Institute of Engineering and Technology

Name of the Team Members along with their respective current semester :

Ashwin Bharathwaj.V (Semester 7)

Poornima.V(Semester 7)

Sowmiya.S(Semester 7)


E-Mail Address & Phone Number of the Team Leader :

ashwinbharathwaj@gmail.com

9659842320

Name of the Faculty Guide :

S.Charles,AP/EEE

E-Mail Address & Phone Number of the Faculty Guide :

charles.siluvaimuthu@gmail.com

9659478930

Project Information

Project Title:

Relay Testing and Monitoring Using LabVIEW

Hardware & Software Used:

DAQ connector board NIDAQ-6221 with Shielded Connector Board(SCB)

NI LabVIEW v2011, NI Test Stand


What challenge/problem are you trying to solve through your application:

1. Manual testing

2. Manual errors

3. High time consumption

4. Less Reliable

5. Less productivity

6. No viewable proof for testing methods

7. Only single relay testing at a time.

How does your application solves the above mentioned challenge/problem:

Automatic testing of relays enable:

1. High reliability

2. High accuracy

3. Multiple relay testing simultaneously

4. High productivity

5. Test report generation as a proof

6. Less time consumption

7. Reduction of the testing cost due to simultaneous testing methods

Description of Project:

In the present, the testing of the relay coils, contactors and switches are

done manually. A few of its process are done using microcontroller based

programming and this causes a lot of problems during interface of high voltages

and currents. Thus the measuring of continuity and over voltage and current for

the equipments becomes difficult and tedious. This further increases the cost of

production of the hardware equipments which may not be feasible by most

consumers.

LabVIEW a virtual instrumentation software can be the best platform to

overcome the drawbacks in the manual testing methods. LabVIEW automates

most of the testing process.

The main objective of using LabVIEW is that it can be used to virtually

test the relay with the required parameters such as input voltage, current,

maximum ranges of voltage, current etc and then implemented using hardware.

This will reduce the cost; time consumed and increases the reliability and

effectiveness of the testing module.

Using LabVIEW the relay is tested automatically for every

parameter and a report is generated for every equipment tested which can be

used for future references. The report shall contain every parameter tested

which will enhance the utility of the component tested.

Insert Images Here:


untitled1.JPG

untitled.JPG

block diagram.JPG

YouTube Link of Video:


http://www.youtube.com/watch?v=PbAcO8Rd0Uo&feature=youtu.be

Insert the Video here:





Download All
Comments
NIYANTRA
Member
Member
on

Please ensure you have also filled the form (http://natinstindia.com/national_instruments/NIYantra-2013-Round2.html ) and completed the submission process. Ignore this if you have already filled this form.

Contributors