The Daily CLAD

Community Browser
cancel
Showing results for 
Search instead for 
Did you mean: 

Re: SubVI Terminals

SercoSteveB
Active Participant

Consider the two SubVIs called in the screen capture below.  Both use the 4x2x2x4 connector pane have a single connected terminal.  These are identified as Terminal 'A' for SubVI #1 and Terminal 'B' for SubVI #2. 

Which of the following is\are TRUE regarding the Terminals. 

Terminal Types.png

a) A and B are connected to different areas of the Connector Pane

b) A is linked to a Control within SubVI #1 and B is linked to an Indicator within SubVI #2

c) LabVIEW Cleanup Wire has modified the direction Terminal A exits the call to SubVI #1 

d) Steve has adjusted the screen capture through the power of GIMP

Comments
Not applicable

B

asbo
Member

B

LordNobady
Member

I go for D


Learning LabVIEW since January 2013
swetha.sadhula
Member

B

crossrulz
Knight of NI

B


GCentral
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines
"Not that we are sufficient in ourselves to claim anything as coming from us, but our sufficiency is from God" - 2 Corinthians 3:5
DesasterMaster
NI Employee (retired)

I would say D

--------------------------------------------------------------------------------------------------------
Work with NI Hard- and Software for about 15 years now.

Certified LabVIEW Developer & TestStand Developer/Architect

--------------------------------------------------------------------------------------------------------

There are only two ways to tell somebody thanks: Kudos and Marked Solutions
MustafaJama50
Member

B makes sense!

MrStevenUND
Member

I don't doubt Steve's truely awesome powers of GIMP, but I'm going with B.

nik35324
Member

B

Amiri
Member

I didn't understand the question/situation at first, but I think I got it...

B

eleshrudra
Member

i didn't understand. please some one explain.....

R.Elesh
SercoSteveB
Active Participant

Answer: B.  Nice one AustinManinTown, asbo, swetha.sadhula, crossrulz, MustafaJama50, MrStevenUND, nik35324 & Amiri

Has anyone ever tried wiring controls to the right hand side of the connector pane and indicators to the left hand side, then enabling highlight execution and watching the VI dataflow run right to left? 

SercoSteveB
Active Participant

Hi eleshrudra, can you be more specific?

Not applicable

eleshrudra, If you associate the terminals on the top right hand corners of the VI connector with a control, LabVIEW will show the wire stub as pointing up (Picture A).  If the connector is associated with an indicator the wire stub points to the right (Picture B).

eleshrudra
Member

hi steve ,

i got it will flow as leftt side, top and botom side of sub vi as control part and right side as a indicator am i right?

programming flows from left to right.

R.Elesh
eleshrudra
Member

Thank you AustinManin Town

R.Elesh
eleshrudra
Member

thank you steve .

R.Elesh
Gab008
Member

a

Kuddo welcomed
CLAD-CTD
levonsg
Member

B

https://images.youracclaim.com/size/340x340/images/2edb5b1a-9414-44e1-8519-c774fc6dd079/36015_Certificate_Badges_FINAL__1__NI_Instructor_v5.png