09-16-2015 01:21 PM
I have experience with this.
You need to make sure that the ethernet adapter on your computer is the first in the connection order or you need to have wireless turned off. The issue is that the LNA, when connecting, sends its IP address to the receiver so the receiver can connect back to it. It will send the IP address for the first active adapter in the connection order.
This is under Network Connections/Advanced/Adapters and Bindings.
.
Phoenix, LLC
CLA, LabVIEW Champion
Check Out the Software Engineering Processes, Architecture, and Design track at NIWeek. 2018 I guarantee you will learn things you can use daily! I will be presenting!
09-16-2015 01:25 PM
Here is a second option. When running from the IDE the message classes can load at run time. Building the EXE removes unused message classes. You need to include the class constant for each LNA message in the build. I usually override Pre Launch Init in the parent actor and put the message class constants there. That way they will be in both the PC and RT builds.
Phoenix, LLC
CLA, LabVIEW Champion
Check Out the Software Engineering Processes, Architecture, and Design track at NIWeek. 2018 I guarantee you will learn things you can use daily! I will be presenting!
09-16-2015 01:44 PM
interesting. I will have to sit down and dissect what you have written here. On the first one, I think the wireless is disabled, I have a switch on the side of my development laptop that shuts it off, but I dont go into the network settings and explicitly disable it. on the second one....that will take me a little time to digest. I have a meeting to run off to, so will have to look back at this. Thanks for your reply, I certainly appreciate it Casey.