09-18-2011 04:33 AM
I am trying to connect a the arduino with a bluesmirf RN-42 via windows mobile 6 and cannot connect. With the digital write vi there is a vi named checked for pin out of range when I try to compile that under windows mobile and It says property node not supported in current target.There is a picture of the vi below and I have attached the "check for pin out of range.vi'. The property nodes that are not working are the names and callers in the digitial/analogue loop. Is there any way around this?
Any help is greatly appreciated
Canalian
09-19-2011 09:54 AM
Canalian,
We never did any verification on LabVIEW for Mobile in regards to LIFA. The picture you attached did not show up but I imagine the only property node used is a VI Server property used to identify the VI for error checking. If this is the only issue with porting your application to a mobile device, I would actually recommend deleting every instance of the Check for Pin Out of Range. Using this you will have to do pin range checking by hand (essentially making sure on a Uno that you don't use Digital line 20) but it will get rid of this issue.
-Ben