11-16-2012 03:28 PM
Hello,
I am trying run to get_HTTP (Get.vi) on an RT target (cRIO-9014, LabVIEW 2011 version) to access a webpage on a Linux machine. I am getting the error as given below: (It works fine when I run this on my Windows machine).
Error 7 occurred at Call Library Function Node in LabVIEWHTTPClient.lvlib:GET.vi->get_HTTP.vi
Possible reason(s):
LabVIEW: File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS X, and / on Linux. Verify that the path is correct using the command prompt or file explorer.
=========================
NI-488: Nonexistent GPIB interface.
HTTP client VIs (Get, Post, PUt , etc.) are supported on RT targets? Is there any workaround to fix this problem?
Appreciate your input......
12-10-2012 12:44 PM
Hello Vasudevks,
The error you are receiving is due to not having HTTP support installed on your real-time target. You can install that software using Measurement & Automation Explorer. We have made a note of this and will be updating the error code to be more specific.
01-04-2016 12:59 PM
As of LabVIEW 2015 it appears this Error Message has not been updated to be sufficiently specific. It still gives a general error that a file is missing.
04-19-2016 12:48 AM
same problem with Crio 9066.