hi Eric,

 

see attachment for Y800 error in NI Example prgm.

 

thanks for your time and effors

0 Kudos
Message 11 of 15
(1,395 Views)

I saw the same error when I ran the program too.

0 Kudos
Message 12 of 15
(1,386 Views)
Solution
Accepted by lgwilson

Hi everyone,

 

I was just able to verify that this is a bug in the software and a request has been submitted for it to be fixed in the 2013 version of the Vision Development Module.  The current workaround is to use the old API. Some of you mentioned having issues with WMP. This discussion on the Microsoft Community may help you resolve the issue.

 

 

Applications Engineer
National Instruments
Message 13 of 15
(1,371 Views)

Thanks for getting back to us Eric - I'll look forward to the next release, but it's good to have a workaround in the meantime.

Message 14 of 15
(1,364 Views)

AVI2 create bug.png

 

Workaround:

Just connect a dummy string to the compression filter input and ignore error -1074396006.

 

NacNuds

0 Kudos
Message 15 of 15