01-19-2013 12:06 AM
I get an error stated the shared library corresponding to external model returned an error with code M202 . I have LabVIEW 2012 version and Multisim 12.0.1 versions installed . I followed the steps that were given in the manual. Is there anyother configuration i need to do ??? i tried to change the minimum, maximum step sizes . but still i am facing this error.
thanks in advance 🙂
Solved! Go to Solution.
01-21-2013 09:02 AM - edited 01-21-2013 09:03 AM
Hi Rakesh,
I looked up the file. The problem is that the input terminal is not connected.
If you grab it and move it on the schematic you will find it's floating.
Please make sure it's connected.
Thank you,
Mahmoud W
National Instruments
01-21-2013 12:27 PM
hi Mahmood,
thanks a lot 🙂 it worked perfectly 🙂
07-04-2013 03:01 AM
Hi,
I have an error code 2367, I am attaching the miltisim and labview files. I tried to changing the time step in multisim also, but I am getting same error.
Could you please help me.
Thanks
07-04-2013 03:03 AM
Sorry, I didn't attach the multisim file in previous, now I am attaching......
07-08-2013 06:52 AM
Hi all,
Could you please help me any one about my previous message. I really need some one help......
Thanks in advance.....
07-08-2013 09:45 AM
Hi Sulochana,
To guarantee quick response, please post your question to a new thread.
I looked into your files, the timing setup of your simulation loop is probably the issue. Try to replicate the same timing setup in one of the sample examples using the Runge-Kutta 23 Solver Method.
Mahmoud
07-08-2013 10:26 AM
Hi Mahmoud,
Thanks for your reply.
I tried same timing setup as in Runge-kutte 23 solver method, but still same error occuring. What I do now? I applied same method for another program it is working. finally when I apply for this method same error, Is there any other problem. I constructed the multism circuit so many times, still same problem...
Please let me know if any solution. I have to solve this error otherwise my work will not move.
Sulochana