08-17-2018 02:59 PM
I am running test stand/labview set up on multiple machines. I have one machine that will not display a sequence list while running (rest of them are fine). The screen is blank until sometimes near the end of the sequence and even then it is not synchronized with what is happening. The test sequence is doing what it is supposed to do otherwise
Hope this makes sense to someone, I can add some screen shots if it helps clarify.
Have a nice weekend
Solved! Go to Solution.
08-17-2018 03:27 PM
Do you mean completely blank? Or just most of the TestStand screen? My initial guess is that tracing isn't enabled. Check at Execute->Tracing Enabled or Configure->Station Options->Execution->Enalbe Tracing
08-20-2018 07:06 AM
That did it :). Thanks for taking the time to help. I've been using labview for years but am still new to test stand