12-16-2014 06:05 AM
Hi,
i'm using a 64-relays-matrix with my NI-PXI-2567 module. It's includes an 3x18 matrix with 3 channels for 18 pins.
To make it easier in LabVIEW, i created routes for every posibiliy: CH1_TO_PX , CH2_TO_PX, CH3_TO_PX (X represents a number from 1 to 18)
For example, if I want Pin 1 connect to CH1, Pin 6 connect to CH2 and Pin 15 connect to CH3, the following routes need to be switched: CH1_TO_P1, CH2_TO_P6, CH3_TO_P15.
Question: What string do i need to connect to the "niSwitch Connect Channels(Mulitple).vI" to make this work?
I tried it like this:
Unfortionatly, the error message says that there needs to be at least one arrow (->) in the string.
Doens't Labview take the String from the Route Setup? (see marked string in first picture bottom right)
What is the correct string that I need to use?
Solved! Go to Solution.
12-16-2014 09:03 AM
Bommelchen,
The thing that you are configuring in in NI Switch Executive. You will need to connect using NI Switch Executive if you wanted to configure the routes in MAX. See below for more information on using switch executive.
NI-SWITCH uses the channel names that the device has at default. If you choose to use NI-SWITCH you can only use a string such as "ch0->com0" using the default names of the device.
08-03-2016 03:35 AM
i have this problem