12-05-2006 04:50 PM
I have ran into this problem a few times. It seems to be a problem with an source code control (SCC) provider being configured and opening a LabVIEW project before opening the problematic VI or VIs. If I load the VI without any project opened then the column separators (in edit mode) function as they should. If I open up my project first (w/configured SCC) then the column separators don't work on some of the VI's.
One way I was able to fix it was to disconnect from my SCC provider(currently Visual SourceSafe). Now all VIs which were giving me problems before are no longer an issue. From other posts I have read it seems this is a problem with other SCC providers as well. Maybe it has to do with SCC providers using the WinCIWrap.dll. I do not believe PerForce uses this dll. Anybody using PerForce seeing this issue?? NI?