How to set DAQmx Period Task input terminal

Solved!
Go to solution

I have a counter period measurement Task created in VB6.0 using Measurement Studio 8.6 and NI-DAQmx. Is there a way to configure the input (gate) terminal to be PFI0 instead of the default.

Thanks, vecsol..

0 Kudos
Message 1 of 2
(6,846 Views)
Solution
Accepted by vecsol
The counter terminals are hardwired to certain pins on your DAQ card.  The gate terminal isn't set to a "default," the counter gate is wired to a certain PFI line - this cannot be changed.  Check the NI-DAQmx Device Terminals Help for information on which PFI line corresponds to which counter terminal.
Ben

National Instruments
Certified LabVIEW Associate Developer
Certified TestStand Developer