06-09-2009 03:14 PM
Solved! Go to Solution.
06-10-2009 02:14 PM
You should be just fine with RIO 3.1 and LabVIEW 8.5. Please note that 3.1.1 is available on our website at http://joule.ni.com/nidu/cds/view/p/id/1289/lang/en and you will see in the readme that version of LabVIEW past 8.0 are supported.
To verify the minimum software versions of LabVIEW and RIO for your hardware see this link:
ftp://ftp.ni.com/pub/devzone/tut/crio_software_versions.htm
Let us know if you have problems. Be sure to install RIO after all toolkits and modules.
Regards,
Anna K.
06-10-2009 02:21 PM
Thank you Anna,
That appears to be our real problem, we ordered a cRIO-9022 and it looks like that isn't supported until labVIEW 8.6.
Erich